Three weeks in -----Nice package and tool kit. Initial set up went ok. My first candidates were 1" copper type L pipes on a hot water return circulation loop. I used vaseline. The readings were weird - very low, zero and then they went negative and then positive. My M90 signal strength was not very good. I then got a 'Signal Reverse Error' and an error 0400 and it stopped reading.So I ordered some proper ultrasonic gel; no help.In the interim we replaced the pump (it was old) and when i broke it down we discovered the impeller had no blades on it - hence the negative readings.I sent the vendor all the info and some pix and they got back to me overnight - had me reset to original factory specs and I set everything up again and this time I used the proper gel - they said alway reapply anytime you move it. Worked perfectly.I still get the 'Signal Reverse Error' sometimes if I leave the sensors in place too long on a hot pipe - it dries up. So i add another dab and it works fine again.So far very happy with it.
Jose E Mendez
Comentado en los Estados Unidos el 30 de mayo de 2024
No cumple las.especificaciones y donde alcanza a leer tiene un 60 % de error....necesito saber donde retornarla
Emilio
Comentado en México el 4 de marzo de 2024
Funciona muy bien y cumplio con mis expectativas
Customer
Comentado en los Estados Unidos el 8 de noviembre de 2024
Excelente
J Antonio P
Comentado en México el 12 de agosto de 2023
No se pudo cargar el contenido.
pedro s.
Comentado en México el 24 de octubre de 2023
el equipo es excelente la verdad vale la pena y a un excelente precio
Jose D.
Comentado en México el 2 de octubre de 2023
Buenas tardes, recibí el producto en perfectas condiciones mas sin embargo necesito factura y no he podido obtenerla.Saludos!!
Robert Salasidis
Comentado en Canadá el 16 de diciembre de 2022
For relatively good flows, it works reasonably well (good correlation to Keyence flow sensor).At low floors however, it often reads 0, even though there is a low flow happening through the pipe.The chain straps are also a bit awkward for smaller pipes. It would be nice to have elastic velcro straps for those applications.The signal works mostly if you apply an ultrasound gel on the interface to the pipe. This is not included, I use a clinical ultrasound gel myself.
QC Department
Comentado en Singapur el 9 de noviembre de 2022
No calibration certificate included
Miguel Martinez
Comentado en México el 24 de noviembre de 2022
El equipo es lo que necesitaba, y funciona correctamente, Gracias