Acerca de este artículo

  • Para su uso con cualquier panel de interruptor principal o interruptor de transferencia nuevo o existente.
  • Diseñado para la instalación en cualquier panel de transferencia manual o centro de carga listo para generador.
  • Sonido de una alerta audible de 86 dBA (@30 cm) en caso de que se produzca una salida de energía.
  • Conozca exactamente cuando se restaura la energía eléctrica después de la salida
  • Funciona con pilas con indicador de batería baja.


Reliance Controls THP108 POWER BACK Alarma de retorno de red. Se conecta a través de un orificio ciego en la parte superior de un centro de carga residencial. El cable del detector de voltaje se enrolla alrededor del cable de entrada de servicio. Suena la alarma cuando se restaura la energía. cULus listado. Desde 1909, Reliance Controls Corporation ha contribuido con más innovaciones que cualquier otro fabricante y ha obtenido más de 85 patentes sobre interruptores de transferencia manual, interruptores de tiempo y accesorios. Reliance Controls Corporation se especializa en la fabricación de una amplia variedad de productos eléctricos. La línea principal de productos consiste en relojes y controles de tiempo pesado, accesorios para generadores, interruptores de transferencia y paneles de transferencia para generadores portátiles. e inversores. Y después de más de un siglo de innovación, Reliance Controls Corporation ha construido una reputación envidiable por su alta calidad, ingeniería superior y excepcional servicio al cliente.


Mikholmes
Comentado en los Estados Unidos el 31 de enero de 2025
Installing on an outside panel and this was installing on an outside panel and this control is not rated to be placed outside. I purchased the weather proof box  from Amazon and installed the control inside the box. When I have to go out and turn it on in a power failure i just leave the door open so I can hear it when power is restored. Then I turn it off and close the door. Wiring it. To test it without the meter being pulled and power still on in the panel i did this. I used a branch circuit from the panel. A 15 or 20 amp will work. I turned off the breaker and wrapped the white section of the wire around the circuit wire leaving the breaker and used a wire tie to temp hold it around the wire. Then turned on the power to the was installing on an outside panel and this control is not rated to be placed outside. I purchased the weather proof box  from Amazon and installed the control inside the box. When I have to go out and turn it on in a power failure i just leave the door open so I can hear it when power is restored. Then I turn it off and close the door. Wiring it. To test it without the meter not being pulled and power still on in the panel i did this. I used a branch circuit from the panel. A 15 or 20 amp will work. I turned off the breaker and wrapped the white section of the wire around the circuit wire leaving the breaker and used a wire tie to temp hold it around the wire. Then turned on the power to the unit no sound. but when I restored power to the break the alarm sounded telling me the system was working. . Now turn off the breaker remove the white wire and install it around one of the 2 wires going to the main breaker in the panel Either wire will work. Be careful as those wires will have current on them unless you pull the electrical meter or have a disconnect switch before the panel which you can turn off. no sound. but when I restored power to the break the alarm sounded telling me the system was working. . Now turn off the breaker remove the white wire and install it around one of the 2 wires going to the main breaker in the panel Either wire will work. Be careful as those wires will have current on them unless you pull the electrical meter or have a disconnect switch before the panel which you can turn off. control is not rated to be placed outside. I purchased the weather proof box  from Amazon and installed the control inside the box. When I have to go out and turn it on in a power failure i just leave the door open so I can hear it when power is restored. Then I turn it off and close the door. Wiring it. To test it without the meter not being pulled and power still on in the panel i did this. I used a branch circuit from the panel. A 15 or 20 amp will work. I turned off the breaker and wrapped the white section of the wire around the circuit wire leaving the breaker and used a wire tie to temp hold it around the wire. Then turned on the power to the THP108 no sound. but when I restored power to the break the alarm sounded telling me the system was working. . Now turn off the breaker remove the white wire and install it around one of the 2 wires going to the main breaker in the panel either wire will work. Be careful as those wires will have current on them unless you pull the electrical meter or have a disconnect switch before the panel which you can turn off. Yes the white wire can be loosely wrapped as I did because the white wire picks up the inductive current from the power wire to the mail breaker
GARY
Comentado en Canadá el 10 de agosto de 2024
It installed easily and we were using it for a backup generator use. We are manually switching the main and Generator breakers to facilitate a change from Hydro line power to Generator power. When running on Gen power and should the Hydro power becomes active/available, this device alerts you to switch generator breaker off and activate the Main breakers.
Mike B.
Comentado en los Estados Unidos el 21 de octubre de 2024
I only learned of this item from an online forum. It has been worth every penny. This has ONE job and does it perfectly! The moment power is restored by local utility company, it sounds a distinct alarm notifying me to turn off my portable generator and swap back to utility source.Easy to install.Image: Green line = Ground wireYellow line = Sensor wire
Jacinthe Sergerie
Comentado en Canadá el 3 de abril de 2024
Très utile lorsque l’électricité reviens suite à une panne.
Bob
Comentado en Canadá el 25 de marzo de 2023
Worked perfect to tell me when to shut the generator off.